#208 Issue closed: hpacucli show config output changed

Labels: bug, fixed / solved / done

pavoldomin opened issue at 2013-03-19 15:31:

Hi

The recent hpacucli version lists output differently (hpacucli version 9.30.15.0), logicaldrive line is now BEFORE array line

#hpacucli ctrl all show config

Smart Array P420i in Slot 0 (Embedded)    (sn: 5001438021794040)


      logicaldrive 1 (136.7 GB, RAID 1, OK)
   array A (SAS, Unused Space: 0  MB)


      physicaldrive 1I:2:1 (port 1I:box 2:bay 1, SAS, 146 GB, OK)
      physicaldrive 1I:2:2 (port 1I:box 2:bay 2, SAS, 146 GB, OK)

   SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 380 (WWID: 500143802179404F)

This breaks expectations in layout/save/GNU/Linux/27_hpraid_layout.sh and results in wrong (or none) logicaldrive description in disklayout.conf.

It may be also related to #176.

jhoekx commented at 2013-03-19 15:38:

I noticed this does not even work anymore on my systems. I will find a solution (not this week).

gdha commented at 2013-07-29 18:23:

@jhoekx kind reminder ;-) to fix the bug in the coming weeks (please...)

gdha commented at 2013-10-02 12:18:

@pavoldomin is it possible to attach via gist the output of rear -vD savelayout?

gdha commented at 2013-12-04 15:03:

@pavoldomin could you give it a try (with rear-1.15-git201312041558)?

pavoldomin commented at 2013-12-05 10:00:

I will.. Btw, recent (September) HP SPP obsoleted hpacucli, and basically renamed the tool to hpssacli. Should work same as hpacucli.

gdha commented at 2013-12-12 15:44:

@pavoldomin could you give the snapshop a try at http://download.opensuse.org/repositories/Archiving:/Backup:/Rear:/Snapshot/

gdha commented at 2014-04-02 16:12:

@pavoldomin may I close this issue? I think it works (at least for me)

gdha commented at 2014-05-06 07:31:

rear-1.16 is out and fix is included


[Export of Github issue for rear/rear.]