#351 Issue closed
: Regression due to commit : created a new function define_HPSSACLI to find proper Smart Storage ...¶
Labels: bug
Florent38 opened issue at 2013-12-19 07:34:¶
Hi,
Running rear mkbackup -Sv
Press ENTER to include '/usr/share/rear/layout/save/GNU/Linux/27_hpraid_layout.sh' ...
ERROR: HP Smart Storage Administrator CLI not found: hpacucli nor hpssacli
Aborting due to an error, check /var/log/rear/rear-cuba13.log for details
The beginning of /usr/share/rear/layout/save/GNU/Linux/27_hpraid_layout.sh
# Code to recreate HP SmartArray controllers
define_HPSSACLI # call function to find proper Smart Storage Administrator CLI command - define $HPSSACLI var
Rear call the define_HPSSACLI command.
function define_HPSSACLI() {
# HP Smart Storage Administrator CLI is either hpacucli or hpssacli
if has_binary hpacucli ; then
HPSSACLI=hpacucli
elif has_binary hpssacli ; then
HPSSACLI=hpssacli
else
Error "HP Smart Storage Administrator CLI not found: hpacucli nor hpssacli"
fi
}
On my workstation :
type hpacucli
type: hpacucli : not found
type hpssacli
type: hpssacli : not found
So I always get this error message.
See 4ddb027623bf5a8885ea532540bde3ca368a0bee
[Export of Github issue for rear/rear.]